Please see below for important warranty information. Filter results by category, title and symptom. 1. Nov 12, 2018 · This is a BRAND OEM NEW Rheem/Ruud/Weather King/Corsaire Gas Furnace 2 Stage Air Pressure Switch. Documents. Aug 18, 2010 · I purchased this item to replace a failing pressure switch on my Rheem Criterion II Gas Furnace. RESULT: Pressure switch stuck open, switch will not close when inducer is on. The inducer and other fans start The surface igniter does not glow (just replaced) No other sounds or clicks No evidence of gas fans shut off It will continue OEM Rheem RUUD Furnace Air Pressure Switch Replaces 42-22905-06 1. Filter results by part category, part title and lawn mower symptoms. 13. 3. The model # of the furnace is Ruud Silhouette II gas furnace ugph-ioeamer serial # ev5d302f409702077. The Rheem/WKing/Corsaire/RUUD Part # is 42-24166-86, which is a kit Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. Problem: Last year and this year when we start needing the furnace to run more and more, Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. Remove that rubber hose, and blow the hose out and tap the pressure switch and see what happens Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. 45 $ 43. Ruud Gas Furnaces Replacement Parts For Model UGPH-05EAUER . This is a Brand New OEM Replacement Air Pressure Switch. Hello - Have a Ruud Silhouette II gas furnace, Need to fix your Ruud Furnace UGLH-07AUER? Use our UGLH-07AUER Parts, diagrams, manuals, and videos to make your repair easy. This is a brand new Rheem/Ruud/Weather King/Corsaire Upgraded Furnace Air Pressure Switch. G22-473 Rev. The 42-24194-82 Rheem Ruud Furnace Pressure Switch Kit replaces pressure switches: 42-101233-02, 42-23648-03, 42-24064-01, 42-24194-02, 42-24335-03 and 42-22682-03. The right green light flashes a few times, stops, and then flashes again, and the left green light is steady. Oct 16, 2021 · How Much Does it Cost to Replace a Pressure Switch on a Furnace? The cost to replace a furnace pressure switch ranges from $50 to $350, depending on multiple factors such as the type of furnace, type of switch (low-pressure or high-pressure), and so forth. Top Qualty OEM Replacement Part! › See more product details. 45 Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. Get genuine Ruud factory OEM Inducer Draft Assemblies for your Ruud HVAC unit. The blower will run for about 30 seconds and then turn off. This is a new upgraded replacement furnace air pressure switch silhouette ii Troubleshooting! Rheem. ADD TO CART Ruud Furnace Pressure Switch ClimaTek Furnace Vent Air Pressure Switch - Fits Rheem Ruud Part # 42-101955-02. Dec 23, 2020 · I troubleshoot it to the pressure switch intermittent through the codes that it’s showing on the unit. This list of independent third-party contractors who exercise independent judgment and are known to sell and / or service Rheem / Ruud heating and air conditioning equipment is strictly for your convenience. ca Oct 1, 2013 · OEM Replm for Rheem 42-23648-03 - Rheem OEM Furnace Replacement Air Pressure Switch Recommendations Nordyne 632432 - OEM Furnace Replacement Air Pressure Switch 0. Results 1 - 30 of 89 — Ruud silhouette ii manual - Amazon S3. Any idea on what causes Ruud Furnace Model UGDG-10EAMER Parts. Ruud 42-105601-21 RUDD PRESSURE SWITCH. VAWL-VHGL R410A 50Hz - _HGL Arabic IOM; VAWL+VHGL Series 60Hz - _HGL Arabic IOM; VAWL+VHGL Series 60Hz - _HGL English IOM; VAWL-VHGL R410A 50Hz - _HGL English IOM I have Ruud Silhouette II gas furnace. will not reach temp. Easy job once you find the right part for your furnace. 3 Flash: High limit or auxiliary limit open. Jul 21, 2017 · Connect the electrical cord on the Ruud furnace firmly to a power outlet if nothing on the furnace will work. X 18" Replaces Rheem Ruud Weatherking 79-21491-83 4. Nov 12, 2012 · I have a ruud silhouette ii that stops at step 6 of the below sequence, so I'm not sure if the gas valve is opening. Oct 1, 2013 · About this item. The trouble code was "two blinks", which means "pressure switch open" according to the troubleshooting flowchart. When the pressure switch remains perpetually closed, it could be pointing to an underlying issue in the system. Why Isn T My Ruud Furnace Working? Check the pressure hose and port on the inducer assembly for leaks or blockages. Genuine OEM Part # 42-24194-82 | RC Item # 2637745 Pressure switch-This pressure switch kit replaces pressure switches: 42-101233-02 SILHOUETTE ® II 80. Ruud PD425142 Pressure Switch -0. Find the right Ruud Furnace Model UGPH-07AUER/Serial: EQ replacement parts for your repair. Pressure switch Mar 24, 2023 · Ruud Air Conditioner Leaking Water. Oct 27, 2017 · New member here. Ignitio … read more May 5, 2024 · 1. Yesterday, I tried the solution below (clearing the tube leading to the switch & also blowing/sucking on the tube - and I was able to hear the "click"). 60" w/c with 2 wiring terminals and one hose port. Furnace shut off after a few seconds. 2 out of 5 stars 29 $37. 7% A. Pressure switch closed Ruud Furnace Pressure Switch. Oct 1, 2013 · NO ADDITIONAL COST: You pay $0 for repairs – parts, labor and shipping included. Repair for less! Fast, same day shipping. I Tested The Ruud Silhouette Ii Pressure Switch Myself And Provided Honest Recommendations Below Disclaimer: Information in questions, answers, and other posts on this site ("Posts") comes from individual users, not JustAnswer; JustAnswer is not responsible for Posts. 0 5. Ok. 95. 4 Blinks – Pressure switch stuck closed. ON – Control is powered This 42-101955-02 Pressure Switch is a genuine replacement part for furnaces and is available now from Repair Clinic. Parts Town has the largest in-stock inventory of genuine OEM Ruud parts with fast same day shipping until 9pm ET. BillyHvac. The 42-24194-82 pressure switch is a brand new Rheem Ruud factory authorized furnace pressure switch which comes in a factory authorized parts box. My 20 year old split system has finally given up the fight and needs to be replaced. It has one hose port, two wiring terminals, and is rated at -0. pressure switch (n Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. $41. tengo un equipo Ruud Silhouette II, al encenderlo los quemadores permanecen unios 10 segundos prendidos y se apagan, posteriormente al prende el piloto pero no los quemadores, he limpiado los sensores. Pressure switch closed? Can't find a diagram that. If you look at the serial number you will probably see an F in the middle regarding the 4 numbers following that F If the number is ***** (earlier) than 3702 then you will need part number 42-24194-82 If the number is ***** (later) than 3702, then you need part number 42-101233-81 You can order these online or purchase them locally from a Rheem or Ruud distributor (if you can find one, and The Rheem Pressure Switch is a protective device that opens and causes the HVAC system to stop operating under certain conditions which may be harmful. Ruud Furnace Model UGDG-10EAMER Parts are easily labeled on this page to help you find the correct component for your repair. 35" Rating Required Select Rating 1 star (worst) 2 stars 3 stars (average) 4 stars 5 stars (best) Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. 6 Blinks – Line and Neutral reversed: POWER LED: OFF – No power (24VAC) to control board. Oct 29, 2010 · This means the pressure switch is closed and it shouldnt be. help find the right LIMIT switch for my gas furnace. Ruud OEM Inducer Draft Assemblies. It stopped working correctly 4 days ago. Why Won't My Furnace Light?I get this question a Dec 6, 2015 · G22-473 REV. May 10, 2024 · In this article, I will share with you all the essential information about this innovative pressure switch, from its features to its benefits. There is no gas flow to light when the ignitor clicks to light Contractor's Assistant: Did you double-check the thermostat? Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. 95 $ 34. Nov 12, 2020 · Had an issue with bad contacts in the pressure switch. D. 30" WC 4. 14. Switch will not open. Can you verify the (vent) spill switch is closed or open? The 42-24196-81 Rheem Ruud Furnace Pressure Switch Kit is a brand new OEM Rheem, Ruud furnace pressure switch kit which comes in a Genuine Protech factory OEM parts box. Blink Code 4. 60" W/C. 2. We do NOT have a manual. Answered by BillyHvac in 4 mins 13 years ago Dec 27, 2016 · Video on replacing the (Rollout Switch) on a RUUD A/C and gas heating unit. The prior system managed to heat and cool great, and the installer feels it was properly sized for our home. Cost Find Ruud Switch Replacement Parts at RepairClinic. on thermostat. I have a green light blinking twice but don’t know what the code is. 99 Dec 1, 2022 · The Ruud Silhouette II is a popular line of residential gas furnaces that are commonly used in homes to provide supplemental heating. checked post on board for the ignitor with a wire to ground and got a single spark out of it during the ignition cycle. Observations: furnace is non-repsonsive to heating temperature adjustments. Get genuine Ruud factory OEM Blower Motors for your Ruud HVAC unit. Oct 20, 2018 · working on a ruud silhouette ii model number UGPH-07EAMGR furnace with an ignition issue. Check the fuse or circuit breaker and replace or reset as needed. Customer: I have a RUUD Achiever 90 furnace - Model: UGRA-09EZAJS. Contractor's Assistant: I understand that you're experiencing an issue with your Ruud Silhouette II Furnace, and the flashing green light on the right is a concern for you, but I'm confident that our HVAC Technician will be able to help The common fix I see for this is that most furnaces have a 3 amp fuse that needs replacement on the furnace electrical board but I can find no such fuse on this older Ruud silhouette model. just bought this house it was empty about 8 months. *pics of all components with model info, etc should be attached* I bought a Honeywell Home RTH9585 Smart Color Thermostat, to replace the Robertshaw Model 9500 thermostat I have, which is to be connected to my Ruud Silhouette II Plus 2 gas furnace (model Number UGPK-05EAUER). 95. 80 (1 review) Write a Review Dec 1, 2022 · The Ruud Silhouette II is a popular line of residential gas furnaces that are commonly used in homes to provide supplemental heating. OEM Rheem RUUD Furnace Air Pressure Switch Replaces 42-23648-02 . 0 out of 5 stars. Furnace Disassembly –. Customer: I have a Ruud Silhouette II plus 2 gas furnace in my home. Inspect it for cleanliness. Feb 23, 2018 · Ruud gas furnace keeps shutting off and tripping the limit switches in the front. A Ruud air conditioner that’s leaking water has a blocked condensate drain, dirty or frozen evaporator coils, or the AC is badly installed. F. 42-24335-16 Nov 8, 2014 · Gas and Oil Home Heating Furnaces - Ruud Furnace - Intermittent Problem - Ruud Silhouette II Furnace installed about 1999 (we bought house in 2005). We have fast FREE SHIPPING on all orders over $99 and ship all orders within 1 business day. Apr 8, 2020 · Need some insight. Sep 22, 2015 · ClimaTek Furnace Vent Air Pressure Switch - Replaces Rheem Ruud Weather King Part # 42-24012-01, 42-24387-01 1. The pressure switch in a furnace detects proper ventilation of the unit. 5 ton Weatherking Condensor and a 100k Ruud Silhouette II furnace. When the thermostat is switched to "on", the fan starts up, the furnace ignites the flame, flame comes out and fires from anywhere between 2 to 10 seconds then goes out. Pressure Switch - Before F3702 Obsolete - Not Available. Rating Required Name Email Required. Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. 75" Shaft Long post, my apologies but I'm trying to be as thorough as possible. 80 inch $15. U. 60 inch is a genuine OEM repair part. Furnace Repair Help. $34. Spark Ignitors,Spark Ignitors. 6 out of 5 stars 562 Amazon's Choice Ruud OEM Pressure Switches. If I hit the top of the unit then it will start. We leave fan running 24/7/365. 4 Flash: Flame sensed and gas valve not energized or flame sensed with no "W" signal. One of the key components of any furnace is the air filter, which helps to prevent dust and other airborne particles from entering the furnace and damaging its internal components. R962V Endeavor Line Achiever Plus. 1. 5 amp 1075 RPM's 4 Speed Open Enclosure 48Y Frame Single Phase CCW 3. Take out the sensor. 3/4HP 115Volts 60Hz 9. COVERAGE: Plan starts on the date of purchase. There will be two wires on it that goes to a little switch, sometimes you can tap on the switch lightly with the handle of a screw driver. $2. A blocked condensate drain is the most common cause for a Ruud AC leaking water and can be resolved by draining the standing water and unclogging the drain. 99 Part Number: 42-24335-03. 5 out of 5 stars The Parts Catalog is a complete reference to authorized replacement parts. Ensure that the furnace is receiving proper airflow and that the vents are not blocked. Inspect the limit switch for any signs of damage or malfunction. 4. The inducer motor starts and then the heater lights and runs normally but the motor keeps running for a long time after the big fan stops. 0 out of 5 stars 1 3 offers from $26. Limit Switch - Normally Closed, Close at (-31 Auto)F, Open at 350F, Manual Reset, 120 / 230VAC Part # 47-106130-01 Limit Switch - Normally Closed, Close at 125F, Open at 145F, Auto Reset, 26VAC Aug 18, 2023 · A pressure switch in a furnace is a safety mechanism designed to ensure that combustion gases are properly vented out of the home. Ruud 42-102069-02 Pressure Switch Assembly $18. 5 Flash: Overtemperature switch open. Answered by Douglas in 45 mins 9 years ago Customer: I have a RUUD SILHOUTTE II UGLH-10EAMER, Furnace short cycles,on for about 10 minutes,burner goes off , blower goes off,and then within 2 seconds, combustion fan starts, furnace lights,runs 10 minutes,ect. I Tested The Ruud Silhouette Ii Pressure Switch Myself And Provided Honest Recommendations Below Ruud silhouette ii pressure switch Rich text content rich_text Page comments 107821 Dan has been in the HVAC industry for 23 years with experience ranging from installation and service to sales and distribution. The status light blinks twice, pauses and repeats. Jul 20, 2007 · 2 Flash: Pressure switch or induced draft blower problem detected. Customer: Working on a Ruud Silhouette II furnace, we replaced the induced draft motor and on restart only 1 burner ignited. It also depends on whether you opt for DIY or professional replacement. ever three-star restaurant, in Va, around 90 minutes drive outside D. 0 out of 5 stars 1 rating | Search this page . The fault code on the "OK" LED also indicated a "pressure switch closed" (4 blinks). Does the RUUD Silhouette II Gas Furnace need a pilot light? I hear the blower running but the air Oct 1, 2013 · ClimaTek Furnace Vent Air Pressure Switch - Replaces Rheem Ruud Weather King Part # 42-105601-20, 42-23649-01, 42-24335-20, 42-23564-03 5. could the lack of a pulsating Customer: I have a Ruud Silhouette II gas furnace and I have replaced the ignitor switch, the limit switch, the board, pressure switch. The problem doesn't happen all the time, but thermostat will call for heat then draft inducer motor starts, then HSI glows, then calls for gas and it lights in HSI port only for 1 minute or so then goes out not allowing other 2 ports to ignite. . Customer: Hola, buen día!. com. Manufacturer-approved parts, tools and accessories for HVAC and water heating. A/C works great-no issues. My furnace is now working without any issues. Limit Control Switches,Limit Control Switches. assumed it was the ignitor and replaced it, no luck. Rudd Silhouette II Troubleshooting ManualRud Silhouette II Furnace ManualBridge Screw is not being very careful to damage anything else. Blower turns on when thermostat is set to auto, then turns off after a few seconds. 35. A clogged condensate trap or drain, or a restricted heat exchanger, could also cause the pressure switch to not function. Model: UGPH-07EAUER Serial Number: DF5D302F289604704 Thermostat/controller: Start Right Here Find appliance parts, lawn & garden equipment parts, heating & cooling parts and more from the top brands in the industry here. If o Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. 99 Feb 15, 2014 · Gas and Oil Home Heating Furnaces - ruud silhouette ii not igniting - RUUD Silhouette ii Model # UGPH-10EAMER SER # DH5D302F169601415 Thermostat calls for heat. Installation was simple, as all connections matched those of the old switch. FIX: Try to manually close the switch, replace the switch, or check blowers and vents for air pressure. 5 Blinks – Not applicable. Find the gas valve, usually in the rear of the furnace, and turn it on all the way if there is no heat. See full list on furnaceprices. This is a Brand New HoneywellTrane/American Standard furnace air pressure switch. Draft inducer blower starts. All Ruud Blower Motors are brand new in the original factory packaging and are guaranteed to fit and function properly. This Ruud PD425154 Pressure Switch -0. Start Right Here Find appliance parts, lawn & garden equipment parts, heating & cooling parts and more from the top brands in the industry here. Review Subject Required This Ruud 42-102069-08 Pressure Switch is a genuine OEM repair part. Report an issue with this product or seller. In fact the only fuse I can find is a Type T 15 amp fuse located by the on/off switch. Check the pressure hose and port on the inducer assembly for leaks or obstructions. Dec 29, 2017 · Furnace Air Pressure Switch Fits Rheem Ruud Weather King Corsaire 42-24335-02 0. Discontinued Three flashes typically indicate an issue with the limit switch. Me, John Doe, highly recommend the 42-101955-02 – Ruud OEM Furnace Replacement Air Pressure Switch! As someone who has struggled with my furnace in the past, this product has been a lifesaver. SeattlePioneer I don't know where the pressure switch is. . It is rated at 0. If your Ruud furnace displays four flashes, it signifies a problem with the high-limit switch. Ruud OEM Blower Motors. Nov 15, 2011 · Gas and Oil Home Heating Furnaces - Ruud Silhouette II problem - I have a Ruud Silhouette II heater that won't heat. We live in Oklahoma City, and currently have a 3. Saved a little money by fixing it myself. The flame rollout limit switch monitors the heat surrounding the burners. 2009. All Ruud Inducer Draft Assemblies are brand new in the original factory packaging and are guaranteed to fit and function properly. Because of the Silhouette’s low-profile 34 inch [864 mm] height, the upflow model can also be used to satisfy most applications that traditionally Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. Ruud Furnace Flame Rollout Limit Switch Genuine OEM Part # 47-22861-02 | RC Item # 2638002 Dec 6, 2015 · Gas and Oil Home Heating Furnaces - RUUD Silhouette II Furnace, No Heat - Hello, I have a RUUD Silhouette II furnace that will not heat. I think that the fan that is coming on is the blower motor, it is very loud but I'm not to sure, how can I check. The furnace was working fine up until recently. E. Looks like igniter is not turning on and burners not kicking on. Drops, spills and cracked screens due to normal use covered for portable products and power surges covered from day one. Please see below for important warranty information and a list of models that this part fits. Feb 14, 2024 · – Pressure switch stuck open switch will not close when inducer is on. 2 Ruud Silhouette II Plus 2 LXE gas furnaces are available as optional accessories. Take all the blower wires off the board except the white wire. The draft inducer fan motor assembly creates a vacuum when running which closes the pressure switch. A clogged condensate trap or drain, or restricted heat exchanger, can also cause a pressure switch to not function. May 4, 2015 · OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I. The furnace will kick on but not getting any heat. 99 $ 37 . Click on Shop Parts, or select the kind of product you're working with on the left and we'll help you find the right part. Customer: I also have a Ruud Silhouette II furnace. Ruud Furnace Pressure Switch. On restart same thing happened but after that the main blower kept running with no flame. Rheem Manufacturing ranks as the global leader in the manufacture of high-quality, sustainable, and innovative water heaters, tankless water heaters, air conditioners, furnaces, pool heaters, and HVAC systems for residential and commercial applications, and is a full member of AHRI, the Air-Conditioning, Heating, & Refrigeration Institute. Consumer Literature; Specification Sheet; Warranty Card; Comparison Brochure Feb 7, 2009 · Goldstar and SeattlePioneer, thanks for your replies. The fault code is the pressure switch. Get your furnace back up and running with DIY instructions and OEM replacement parts. 5. Does it matter that the RUUD pressure switch did not Oct 17, 2019 · Streamlined version of a previous video!I thought I was going to have to call an HVAC tech to fix this, which is why it went unfixed for so many years. Oct 1, 2013 · This is a Brand New OEM Replacement Air Pressure Switch ; Top Qualty OEM Replacement Part! Jul 20, 2007 · 2 Flash: Pressure switch or induced draft blower problem detected. Replace the pressure switch if there is proper vacuum or pressure, but the switch is not working correctly. The manual states this is a Pressure switch failure - open position. Customer: I have a Ruud SilhouetteII Furnance. The 42-24196-81 Rheem Ruud Furnace Pressure Switch replaces pressure switches: 42-101956-01, 42-24012-01, 42-24196-01, 42-24387-01. Ruud Documents. 96 / ea. List Customer: Hello, I have a ruud silhouette 2 furnace ugph-07eauer and furnace is having troubles running a normal full cycle. Replace the pressure switch if there is Dec 22, 2011 · Hello - I have a Ruud Silhouette II gas heater that is about 10 years old. 3 Blinks – Limit switch open main limit or roll-out control. So sit back, and let’s dive into the world of the Ruud Silhouette II pressure switch. To order factory authorized replacement parts please call us toll free. Dip Switch Free Installation Commissioning via Bluetooth Technology; Configuration Options: 4-Way Multi-Position; Certifications. I have a Ruud ii Silhouette and the ok light is blinking 4 times. Genuine OEM Part # 42-24194-82 | RC Item # 2637745 Pressure switch-This pressure switch kit replaces pressure switches: 42-101233-02 Customer: I have a Ruud Silhouette 2 gas furnace. If you open the door to the furnace you will see the pressure switch with a rubber hose leading toward the fan. Ruud Silhouette Ii User Manual Reading Free Ruud Silhouette Ii User Manual, This is the best area to get into Ruud Silhouette Ii User Manual PDF File Size . If the inducer fan motor cannot draw enough air through the burners, or if the furnace is not venting properly, the rollout limit switch will open to halt the ignition sequence and prevent the furnace from heating. When you go to test it tomorrow what I would do is this. My old switch was not engaging every time, which would prevent my furnace from turning on. 0%–81. I have an old Ruud Silhouette 2 75,000 BTU 80% upflow gas furnace from 1995, and ever since yesterday the blower motor and inducer stay on after every heat cycle unless I turn the power off to the furnace and wait about 15 mins to turn it back on. Customer: My RUUD Silhouette II plus 2 cycles on, but after 3-5 seconds of the burners going it shuts off and the blower continues to blow for 30 seconds and then shuts off also. UPFLOW/ HORIZONTAL GAS FURNACES The Ruud® Silhouette II line of upflow/horizontal gas fur-naces are designed for utility rooms, closets, alcoves, or attics. $15. Where is it located and is there anyway to With a safe and reliable Ruud gas furnace powering your home’s warmth, Ruud has got you covered for many winters to come. 3 GAS FURNACESSupersedes Form No. Customer: I have a ruud silhouette II heater and sometimes it will not start. Filter was very dirty,we removed it Feb 3, 2018 · The furnace is a Ruud Silhouette Gas II PLus (Model UGPL) furnace and is in the attic, an updraft furnace. Browse our entire line of Ruud gas furnaces below, and when you’re ready to get started just click our Find a Contractor link to talk to a certified Ruud ProPartner contractor today! Where is the pressure switch on a Ruud Silhouette II? How to check it? 2. Problem: furnace is not turning on when temperature falls below the present. STATUS LED: 2 Blinks. 35" WC Pressure Switch Contains: 42-101233-01 (1) Pressure Switch 64-17606-03 (2) Wire & Cable Tie - Nylon Red 4-1/2" 791004 (1) Silicone Rubber Tubing Ruud Silhouette II gas furnace. Reset the switches and after a few hours 1 trips again, problem is in the H Oct 1, 2013 · ClimaTek Furnace Vent Air Pressure Switch - Replaces Rheem Ruud Weather King Part # 42-24194-02, 42-24194-82. Ideal for attics, closets and other storage areas, it features an integrated furnace control, two-speed induced draft blower and washable filter, and is designed to run at less than 100 percent capacity during off-peak usage. Here are some causes of a pressure switch that’s stuck closed: Cracked Pressure Switch Tubing The Ruud Silhouette II is a compact two-stage gas furnace that is rated for inputs of 50,000 to 150,000 BTUs. It is important to note that when a pressure switch is replaced, it is replaced with the exact switch. In Stock . The unit was installed new when the house was built in 1996. Pressure switch-This pressure switch kit replaces pressure switches: 42-101233-02, 42-23648-03, 42-24064-01, 42-24194-02, 42-24335-03 and 42-22682-03. 10. 42-23648-03 - Furnace Air Pressure Switch Replaces Rheem Ruud Weather King Corsaire - USA. It is brand new in the original Ruud factory packaging and is guaranteed to fit and function properly. 365 day right part guaranteed return policy. Draft inducer switch proves pressure. 95 / ea. $43. The unit has a door switch that has to be pressed to run. I have had this switch go bad before so I knew what the symptoms were of it go Oct 28, 2006 · The pressure switch is a round metal piece that is mounted just below the little fan that runs when the burners are on, it will have a short piece of hose that runs to the little fan (purge fan). Can you verify the (vent) spill switch is closed or open? Nov 1, 2017 · I have an old Ruud Silhouette 2 75,000 BTU 80% upflow gas furnace from 1995, and ever since yesterday the blower motor and inducer stay on after every heat cycle unless I turn the power off to the furnace and wait about 15 mins to turn it back on. Clean the sensors slowly with light grades and paper. C. FREE delivery Mon, Jan 29 on $35 of items May 4, 2015 · Furnace Vent Air Pressure Switch - Fits Ruud Gas Part # 42-22682-02 . 2012. 70 Pressure switch-This pressure switch kit replaces pressure switches: 42-101233-02, 42-23648-03, 42-24064-01, 42-24194-02, 42-24335-03 and 42-22682-03. unit cycles properly, blower, pressure switch closes, gas valve opens but no spark for the ignitor. Visit the ClimaTek Store. wnxh syj hpt kehgt xuofidm gytijm drfe ygflepcf osvr ditewf